General characteristics of JW3302XR OTDR
JW3302XR optical time domain reflectometer is a multifunctional test instrument designed for FTTx network. It is mainly used to measure the length, transmission loss, joint loss and other physical properties of optical fiber, and to locate the event point and fault point in the optical fiber line. It is widely used for engineering construction, maintenance test and emergency repair in optical fiber communication system, as well as fiber optic cable development and production test.
In addition to OTDR function, JW3302XR OTDR can also be equipped with optical power meter, light source, visual fault location (VFL) and vibration detection function.
Main functions and features of the JW3302XR optical time domain reflectometer:
Display screen | 800×480, 7-inch TFT color LCD (standard distribution capacity touch screen, with optional resistance touch screen) |
Electrical interface | USB port, Micro-USB port, SD card interface, and 10M/100M Ethernet interface |
Power supply | AC/DC adapter: allowable range of input voltage: 100V ~ 242V (1.5A), allowable range of frequency: 50/60Hz; Output DC: 17V±3V (2A)Internal lithium battery: 11.1V, 6800mAh, 75.48Wh Battery working hours:8h |
Environmental Requirements | Operating temperature: -10℃ ~ 50℃(Battery: 5℃~40℃)Storage temperature: -40℃ ~ 70℃(Battery: 5℃~40℃) Relative humidity: 5% ~ 95%, no condensation |
Overall dimensions and | D×W×H: 252mm×180mm×55mm(including the OTDR module) |
weight | 1.8±0.2kg(including the OTDR module and lithium battery) |
Interface language | Simplified Chinese, English, Russian, or Korean (contact the office for additional language support) |
Technical features of OTDR module
Center wavelength (nm) | AVAILABLE IN 850, 1300, 1490, 1310, 1550, 1625 AND 1650 (SEE APPENDIX B FOR DETAILS) |
Dynamic range (dB) | Up to 46 dB (see Appendix B for details) |
Measuring range (km) | 0.4, 0.8, 1.6, 3.2, 8, 16, 32, 64, 128, 256, and 512(single mode, and1300nm for multimode)0.4, 0.8, 1.6, 3.2, 8, 16 and 32(850nm for multimode) |
Pulse width (ns) |
3, 5, 10, 30, 80, 160, 320, 640, 1280, 5120, 10240, 20480(singlemode) 3, 5, 10, 30, 80, 160, 320, 640 and 1280 (850nm formultimode) |
Refractive index setting range | Adjust in the range of 1.00000 ~ 1.99999 |
Cable correction factor | Adjust in the range of 0.80000 ~ 1.00000 |
Linearity | 0.03dB/dB |
Loss resolution | 0.001dB |
Optical output connector | FC/UPC (standard configuration, Matching: LC/UPC 、 SC/UPC 、ST/UPC) |
Technical features of the VFL function
NAME | CONTENTS |
Center wavelength (nm) |
650nm±20nm |
Output power mW | ≥2mW (typical) |
Operation mode | CW, 1Hz and 2Hz |
Interface type | TOSA |
Technical features of optical power meter
NAME | CONTENTS |
Wavelength range | 850/1300/1310/1490/1550/1625/1650nm |
Power range | -60dBm ~ +3dBm or -46dBm~+24dBm |
Uncertainty of calibration point power test |
Better than 0.22dB (-25dBm, CW, 1310/1550nm) |
Uncertainty | ±5% (-25dBm、CW) |
Uncertainty of power measurement within the optical path |
Better than ±1.5dB |
Technical features of the optical light source function
NAME | CONTENTS |
Output wavelength | Same with the operation wavelength of OTDR module |
Output power | ≥-5dBm(23℃±2℃) |
Operation mode | CW, 270Hz, 1kHz and 2kHz |
OTDR standard module
Module number | Operating wavelength | Dynamic range (dB) | Event dead zone (m) | Attn dead zone(m) |
JW3302XR | 1310/ 1550nm | 32 / 30 | 1.5 | 8 |
JW3302XR | 1310/ 1550nm | 37 / 36 | 1.5 | 8 |
JW3302XR | 1310/ 1550nm | 42 / 40 | 0.8 | 4.5 |
JW3302XR | 1310/ 1550nm | 45 / 42 | 0.8 | 4.5 |
JW3302XR | 1310/1550/1625nm | 37/35/35 | 1.5 | 8 |
JW3302XR | 1310/1490/1550nm | 37/35/35 | 1.5 | 8 |
JW3302XR | 1310/1550/1625nm | 42/40/40 | 0.8 | 4.5 |
JW3302XR | 1310/1550/1625nm | 45/42/42 | 0.8 | 4.5 |
JW3302XR | 850/1300/1310/1550nm | 28/26/37/36 | 1.5 | 8 |
JW3302XR | 850/1300/1310/1550nm | 26/34 /42/45dB | 1.5 | 8 |
Above is standard configuration, other wavelength and dynamic range can be customized according to clients demand.
1. Measuring range ≤1.6km, pulse width of 3ns, and optical fiber end reflection loss of≥40dB, with typical value.
2. Measuring range of ≤1.6km, pulse width of 5ns or less, and optical fiber end reflection loss of ≥50dB, with typical value
* Wifi Optional
* 200~400X Microscope function optional
Copyright © 1998 - 2024 JOINWIT. All Rights Reserved.